Parenteral solutions filtration and preparation systems

  The main advantages of our systems are:

  • The process is fully automated.
  • Automatic CIP cleaning of the prefilter and the sterile filter using injection water, with direct flow and reverse flow, if required.
  • Automatic SIP sterilization of the prefilter and the sterile filter using saturated pure steam.
  • The even flow of the solution through the filter prevents fast clogging and premature deterioration of the filter elements.
  • The storage vessel and the main reactor have the same volume.
  • The filtration system has the ability to automatically air removal (including the filter housing).
  • The solution filter or the filter for sterile filtration of the inert gas, are automatically tested for integrity (built into the control system).
  • Monitoring of the differential pressure for determining the state of the membranes.
  • Inside surface purity – RA <0,4μ.